Detalles
| Producto | |
|---|---|
| Tipo de Producto |
UPS |
| Marca | EATON |
| Modelo | 9130 Transformador PPDM |
| Fases | 2 |
| Tecnologia | OnLine Doble Conversion |
| Tipo de Producto |
UPS Sistema de Poder Ininterrumpido |
| Marca | EATON / PowerWare |
| Linea / Modelo | 9130 Transformador PPDM |
| Tecnologia | OnLine Doble Conversion |
| Capacidad |
3 kvA |
| Tipo | Rack |
| Tiempo De Respaldo | Standart |
| Banco de Baterias | Interno |
| Bypass | Interno Automático |
| Bypass Externo | Incluido en Gabinete PDM |
| Voltaje de entrada |
200v/240v, 2F |
| Voltaje de salida | 120v |
| Modelo del PDM | PDM1-HV-US-P2 |
| Panel de Control | Frontal Leds y Pantalla LCD |
| Tarjeta de Comunicaciones SNMP |
No Incluida |
| Garantia | Un Año en Partes y Componentes |
Incluye:
Puesta en marcha de la unidad en área metropolitana, sin costo. (Si es en provincia se cotizara viáticos y transportación correspondientes).
Fletes y maniobras se manejaran igual que la puesta en marcha.
Condiciones comerciales: Pago: 100% anticipo.
Tiempo de entrega: inmediata 3 piezas únicamente con este precio de promoción.
Validez de la promoción: hasta agotar existencias.
| Captura Instantánea del Producto | |
|---|---|
| Rango de Energía | 700 - 3000 VA |
| Voltaje | 120and 208 Vac |
| Frecuencia | 50/60 Hz (auto-sensing) |
| Configuración | Instalación en Rack |
| Serie del Producto | Powerware |
| General | |
|---|---|
| User Interface | Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
| LEDs | Four status-indicating LEDs |
| Topology | True online, double-conversion |
| Diagnostics | Full system self-test |
| UPS Bypass | Automatic bypass |
| Dimensions | See models table |
| Rail Kit | 4-post rail kit included with all rackmount units |
| EBMs | Ship with a rail kit |
| Remote Emergency Power-off (REPO) | Emergency shutdown control through the REPO port |
| Electrical Input | |
| Nominal Voltage | 120V, 208V, 220-240V |
| Voltage Range | 120V: 90–138 Vac 208/230V: 160–276 Vac |
| Power Draw of UPS (full load) | 700: 5.8A @120V, 3.4A @208V, 3.0A @230V 1000: 8.3A @120V, 4.8A @208V, 4.3A @230V 1500: 12.5A @120V, 7.2A @208V, 6.5A @230V 2000: 16.6A @120V, 9.6A @208V, 8.7A @230V 2500: 20.8A @208V, 10.9A @230V 3000: 14.4A @208V, 13.0A @230V |
| Dedicated Circuit Breaker Rating | 120V: 700–1500 VA: 15A 2000 VA: 20A 2500–3000 VA: 30A 208/230V: 700–2000 VA: 10A 3000 VA: 16A |
| Frequency | 50/60 Hz |
| Frequency Range | 45–65 Hz |
| Electrical Output | |
| Power Factor | 0.9 |
| On Utility Voltage Regulation | ±3% of nominal |
| On Battery Voltage Regulation | ±3% of nominal |
| Efficiency | >95% in high-efficiency mode; >86% in online mode |
| Frequency Regulation | ±3% Hz online |
| Load Crest Factor | 3 to 1 |
| Voltage waveform | Sine wave |
| Load Segments | Two configurable, individually controlled receptacles |
| Battery | |
| Battery Type | VRLA 12V/9 Ah (both internal and external) |
| Battery Runtime | >3 minutes with internal batteries @100% load |
| Battery Replacement | Hot-swappable internal and external batteries |
| Start-On-Battery | Allows start of UPS without utility input |
| Communications | |
| Serial Port | RS-232 standard, for interface to power management software |
| USB Port | HID standard, for communicating with Windows 98, XP,ME and Vista computers |
| Relay Output | Common alarm standard |
| Communications Slot | Optional communication slots (BD Slot) |
| Optional Communication Cards | SNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems |
| Environmental | |
| Safety Markings | 120/208V: UL, CUL, VCCI 230V: CE, GS |
| EMC Markings | 120V: FCC Class B, EN55022 Class B (1.5 kVA and below); FCC Class A, EN55022 Class A (2.0 kVA and above) 230V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2) |
| Audible Noise | <50 dB |
| Ambient Operating Temperature | -20˚C (-4˚F) to +40˚C (104˚F) with batteries and -25˚C (-13˚F) to +55˚C (131 ˚F) without batteries |
| Storage Temperature | 5–90% non-condensing |
| General | |
|---|---|
| User Interface | Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
| LEDs | Four status-indicating LEDs |
| Topology | True online, double-conversion |
| Diagnostics | Full system self-test |
| UPS Bypass | Automatic bypass |
| Dimensions | See models table |
| Rail Kit | 4-post rail kit included with all rackmount units |
| EBMs | Ship with a rail kit |
| Remote Emergency Power-off (REPO) | Emergency shutdown control through the REPO port |
| Electrical Input | |
| Nominal Voltage | 120V, 208V, 220-240V |
| Voltage Range | 120V: 90–138 Vac 208/230V: 160–276 Vac |
| Power Draw of UPS (full load) | 700: 5.8A @120V, 3.4A @208V, 3.0A @230V 1000: 8.3A @120V, 4.8A @208V, 4.3A @230V 1500: 12.5A @120V, 7.2A @208V, 6.5A @230V 2000: 16.6A @120V, 9.6A @208V, 8.7A @230V 2500: 20.8A @208V, 10.9A @230V 3000: 14.4A @208V, 13.0A @230V |
| Dedicated Circuit Breaker Rating | 120V: 700–1500 VA: 15A 2000 VA: 20A 2500–3000 VA: 30A 208/230V: 700–2000 VA: 10A 3000 VA: 16A |
| Frequency | 50/60 Hz |
| Frequency Range | 45–65 Hz |
| Electrical Output | |
| Power Factor | 0.9 |
| On Utility Voltage Regulation | ±3% of nominal |
| On Battery Voltage Regulation | ±3% of nominal |
| Efficiency | >95% in high-efficiency mode; >86% in online mode |
| Frequency Regulation | ±3% Hz online |
| Load Crest Factor | 3 to 1 |
| Voltage waveform | Sine wave |
| Load Segments | Two configurable, individually controlled receptacles |
| Battery | |
| Battery Type | VRLA 12V/9 Ah (both internal and external) |
| Battery Runtime | >3 minutes with internal batteries @100% load |
| Battery Replacement | Hot-swappable internal and external batteries |
| Start-On-Battery | Allows start of UPS without utility input |
| Communications | |
| Serial Port | RS-232 standard, for interface to power management software |
| USB Port | HID standard, for communicating with Windows 98, XP,ME and Vista computers |
| Relay Output | Common alarm standard |
| Communications Slot | Optional communication slots (BD Slot) |
| Optional Communication Cards | SNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems |
| Environmental | |
| Safety Markings | 120/208V: UL, CUL, VCCI 230V: CE, GS |
| EMC Markings | 120V: FCC Class B, EN55022 Class B (1.5 kVA and below); FCC Class A, EN55022 Class A (2.0 kVA and above) 230V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2) |
| Audible Noise | <50 dB |
| Ambient Operating Temperature | -20˚C (-4˚F) to +40˚C (104˚F) with batteries and -25˚C (-13˚F) to +55˚C (131 ˚F) without batteries |
| Storage Temperature | 5–90% non-condensing |